AG真人版

  • <tr id='K7Hqss'><strong id='K7Hqss'></strong><small id='K7Hqss'></small><button id='K7Hqss'></button><li id='K7Hqss'><noscript id='K7Hqss'><big id='K7Hqss'></big><dt id='K7Hqss'></dt></noscript></li></tr><ol id='K7Hqss'><option id='K7Hqss'><table id='K7Hqss'><blockquote id='K7Hqss'><tbody id='K7Hqss'></tbody></blockquote></table></option></ol><u id='K7Hqss'></u><kbd id='K7Hqss'><kbd id='K7Hqss'></kbd></kbd>

    <code id='K7Hqss'><strong id='K7Hqss'></strong></code>

    <fieldset id='K7Hqss'></fieldset>
          <span id='K7Hqss'></span>

              <ins id='K7Hqss'></ins>
              <acronym id='K7Hqss'><em id='K7Hqss'></em><td id='K7Hqss'><div id='K7Hqss'></div></td></acronym><address id='K7Hqss'><big id='K7Hqss'><big id='K7Hqss'></big><legend id='K7Hqss'></legend></big></address>

              <i id='K7Hqss'><div id='K7Hqss'><ins id='K7Hqss'></ins></div></i>
              <i id='K7Hqss'></i>
            1. <dl id='K7Hqss'></dl>
              1. <blockquote id='K7Hqss'><q id='K7Hqss'><noscript id='K7Hqss'></noscript><dt id='K7Hqss'></dt></q></blockquote><noframes id='K7Hqss'><i id='K7Hqss'></i>

                欢△迎光临成都市三为技术有限责任公司官方网站

                南宁市天然气专供管道1-3号测试桩电危害治理项目

                时间:2020-06-08 11:45:35 来源:小编

                现场测试数据:施工前后管道∮电位曲线

                曲线为2014年10月管网公●司提供的电位距离,交直流曲线



                                   曲线  2014年10月管网公司提供的电位距离曲线
                 
                从交流干扰电位曲线看,1-8号桩的管段管道电位,都超过标准规定不超过4V.的要求。较高←处电位已经超过人畜接触管道的电位AC/30V,高电位大电流可以造成管道和接触的人畜触电。

                结果分析

                       5-1      3月下旬-4月上旬管网公☆司间断的管道交直流电位数※据统计表

                管道交流排流现场数据测试统计表

                日期

                阴保桩号

                AC(V.CSE)
                排流前/后

                DC(V.CSE)
                排流前/后

                3.26

                YB001

                15.7

                0.91

                -1.36

                -1.3

                YB002

                10.2

                2.87

                -1.29

                -1.29

                YB003

                5.85

                1.35

                -1.228

                -1.22

                YB004

                1.45

                1.06

                -1.27

                -1.15

                3.28

                YB001

                15.3

                0.48

                -1.35

                -1.32

                YB002

                5.96

                0.62

                -1.32

                -1.32

                YB003

                5.47

                0.602

                -1.22

                -1.24

                YB004

                1.42

                1.06

                -1.173

                -1.18

                3.30

                YB001

                5.01

                0.65

                -1.37

                -1.32

                YB002

                2.582

                0.738

                -1.329

                -1.327

                YB003

                3.453

                0.592

                -1.23

                -1.244

                YB004

                0.951

                1.373

                -1.187

                -1.179

                4.1

                YB001

                15.35

                0.78

                -0.138

                -1.33

                YB002

                5.62

                0.76

                -1.33

                -1.32

                YB003

                5.71

                0.95

                -1.25

                -1.236

                YB004

                1.97

                1.83

                -1.179

                -1.168

                4.3

                YB001

                13.2

                0.71

                -1.41

                -1.33

                YB002

                5.13

                0.68

                -1.33

                -1.326

                YB003

                4.9

                0.83

                -1.23

                -1.24

                YB004

                2.05

                1.97

                -1.17

                -1.17

                4.6

                YB001

                12.6

                0.546

                -1.38

                -1.33

                YB002

                4.35

                0.548

                -1.33

                -1.33

                YB003

                4.59

                0.816

                -1.235

                -1.235

                YB004

                1.89

                1.78

                -1.17

                -1.17

                4.8

                YB001

                13.7

                0.78

                -1.39

                -1.33

                YB002

                5.05

                0.63

                -1.33

                -1.33

                YB003

                4.78

                0.82

                -1.234

                -1.24

                YB004

                1.95

                1.85

                -1.17

                -1.17

                4.10

                YB001

                12.8

                0.58

                -1.35

                -1.33

                YB002

                4.85

                0.59

                -1.33

                -1.33

                YB003

                4.86

                0.838

                -1.23

                -1.23

                YB004

                1.88

                1.75

                -1.17

                -1.17

                 

                 
                    曲线是最★新的2015年4月管网〓公司数据,测试的是1-4号电位桩的交直流电位。曲线表明管道交流电位全部『小于2V.CSE,管道在排出交流电压的▓同时,直流电位也有下降趋势;这样可▅以避免管道电位过高带来的应力①腐蚀开裂问题。

                    管道上的持续干扰电压和瞬→间干扰电压应都低于抗工频干扰电压和抗电∏强度指标,并满足TB/T2832 规定的:交流电气化铁道接触网正常运行状态下管道对地电压△容许值为60V;故障时管道对地电压容许值为430V。


                ?